Gets you to the command interface of the Raid Controller
1
2
3
|
/opt/hp/hpssacli/bin/hpssacli
or
/opt/hp/hpacucli/bin/hpacucli
|
Show the status of the controller and current status of Disks
1
|
ctrl all show config
|
Utility Keyword abbreviations
|
|
Abbreviations | chassisname = ch controller = ctrl logicaldrive = ld physicaldrive = pd drivewritecache = dwc |
hpacucli utility
|
|
hpacucli | # hpacucli# hpacucli helpNote: you can use the hpacucli command in a script |
Controller Commands
|
|
Display (detailed) | hpacucli> ctrl all show config hpacucli> ctrl all show config detail |
Status | hpacucli> ctrl all show status |
Cache | hpacucli> ctrl slot=0 modify dwc=disable hpacucli> ctrl slot=0 modify dwc=enable |
Rescan | hpacucli> rescanNote: detects newly added devices since the last rescan |
Physical Drive Commands
|
|
Display (detailed) | hpacucli> ctrl slot=0 pd all show hpacucli> ctrl slot=0 pd 2:3 show detailNote: you can obtain the slot number by displaying the controller configuration (see above) |
Status | hpacucli> ctrl slot=0 pd all show status hpacucli> ctrl slot=0 pd 2:3 show status |
Erase | hpacucli> ctrl slot=0 pd 2:3 modify erase |
Blink disk LED | hpacucli> ctrl slot=0 pd 2:3 modify led=on hpacucli> ctrl slot=0 pd 2:3 modify led=off |
Logical Drive Commands
|
|
Display (detailed) | hpacucli> ctrl slot=0 ld all show [detail] hpacucli> ctrl slot=0 ld 4 show [detail] |
Status | hpacucli> ctrl slot=0 ld all show status hpacucli> ctrl slot=0 ld 4 show status |
Blink disk LED | hpacucli> ctrl slot=0 ld 4 modify led=on hpacucli> ctrl slot=0 ld 4 modify led=off |
re-enabling failed drive | hpacucli> ctrl slot=0 ld 4 modify reenable forced |
Create | # logical drive – one disk hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0# logical drive – mirrored hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1# logical drive – raid 5 hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5Note: drives – specific drives, all drives or unassigned drives size – size of the logical drive in MB raid – type of raid 0, 1 , 1+0 and 5 |
Remove | hpacucli> ctrl slot=0 ld 4 delete |
Expanding | hpacucli> ctrl slot=0 ld 4 add drives=2:3 |
Extending | hpacucli> ctrl slot=0 ld 4 modify size=500 forced |
Spare | hpacucli> ctrl slot=0 array all add spares=1:5,1:7 |